INTRODUCTION
Single use medical devices’ environmental impact is known to generate sizable carbon emissions over a life cycle compared to a reusable equivalent. The SHTG have recognised the need to evaluate this health technology carbon hotspot as part of the HTA. Specifically, this environmental assessment was appropriate for parallel evaluation alongside a health economic analysis to support the decision-making process.

METHODS
Through the application of HTA and environmental management principles and reporting, the Greenhouse Gas (GHG) Protocols, ISO14040 and Publicly Available Specification 2050, a carbon footprint of single use rhinolaryngoscopes was compared with a reusable equivalent. Process activity data, real world data and secondary data were used to quantify carbon intensity. Data were extrapolated to estimate national GHG emissions and waste volumes. The technologies were categorized using thresholds based on the functional unit, to strengthen support for the HTA decision making process. Sensitivity analyses were performed. Further recommendations were made to promote the use of more sustainable health technologies.

RESULTS
The carbon emissions of a single use flexible rhinolaryngoscope compared to its reusable equivalent was 6.03kgCO2e and 3.26kgCO2e respectively. Data extrapolation (2264 procedures per annum) reveals the annual environmental impact of this technology, throughout NHS Scotland, to be 13,652kgCO2e and 7,381kgCO2e, for the single use and reusable devices, respectively. Raw material acquisition, the use of personal protective equipment and transportation were health technology carbon hotspots. The estimated waste volumes are 12.58 tonnes and negligible volumes of clinical waste per annum for the single use versus reusable equivalent, respectively. This pilot study recommends the use a reusable equivalent in this setting.

CONCLUSIONS
Aligned with NHS net zero targets, these findings confirm the need to perform a parallel environmental assessment of technologies alongside a HTA. LCA is a useful framework to comprehensively assess environmental impact of health technology. Data constraints can be overcome through the use of hybrid methodologies, aligned with HTA principles including transparency and reproducibility to enable sustainable HTA decision making.

You may also be interested in

Peer-reviewed publication

Carbon Emission Impact of Semaglutide in People with Obesity in the UK Using a Disease Modelling Approach

YHEC authors: Matthew Taylor
Publication date: September 2026
Journal: PharmacoEconomics

Abstract

OBJECTIVE: We aimed to assess the carbon footprint and clinical outcomes of once-weekly semaglutide in people with overweight or obesity in the UK using a disease modelling approach. METHODS: A...

Peer-reviewed publication

Comparing Statistically Reliable and Patient-Perceived Improvement Following Hip Arthroplasty: Rasch-Based and Anchor-Based Approaches

YHEC authors: Adam Smith, Damian Lewis, Stuart Mealing, Andria Joseph
Publication date: September 2026
Journal: Journal of Patient Reported Outcomes

Abstract

BACKGROUND: Interpreting meaningful change in patient-reported outcome measures (PROMs) is essential for assessing hip replacement outcomes. The Oxford Hip Score (OHS) is widely used, yet statistically detectable change may not...

Peer-reviewed publication

Mitigating Bias in Health-Related Quality of Life (HRQoL) Estimation Due to Missing Data: A Simulation-Based Study Evaluating Imputation Methods

YHEC authors: Joe Moss, Neil Hansell, Erin Barker, Matthew Taylor
Publication date: August 2026
Publishers: MDPI
Journal: Health Economics & Policy

Abstract

Missing Health-Related Quality of Life (HRQoL) data in clinical studies risk propagating bias into health technology assessments (HTAs) and cost-utility analyses. Despite this, current National Institute for Health and Care...